Don't find out your backup power fails when it matters. Buy a load bank built to prove generators, UPS and standby systems under real, full load — resistive, capacitive or combined resistive-inductive, made to your spec, from 100kW to 6000kW. Bespoke designs built to order in 4–6 weeks.

Why test?

What a load bank does

A load bank puts a controlled electrical load on your generator — just like the real thing — so you can see how it performs at full power before you depend on it.

  • Confirms generators and UPS reach their rated output
  • Finds faults safely, not during a power cut or live event
  • Burns off carbon build-up from lightly loaded engines
  • Gives you test results for compliance and insurance
Generator on site

A load bank is the best way to verify real-life demands on critical power systems

Call 01565 654 004

Three types

Which load bank you need

There are three types of load bank available to have made. Tell us what you're testing and we'll specify the right one — or a combination of them.

kW

Resistive

The straightforward way to prove real load. Resistive elements draw the same kind of load a building or site does, so you can run your generator at its rated kW output.

kVAr

Capacitive

Rated in kilo-volt-ampere reactive (kVAr). Normally used in conjunction with a resistive unit to increase the power factor (PF) to unity, so the test matches the real site condition.

kW + kVAr

Resistive & inductive

A combined unit where the inductive and resistive elements can be switched individually, allowing tests to load 100% of the kVA rating. Combined units may also include capacitive elements if required.

Multiple load banks can be paralleled together to test larger capacity generator systems, so a site bigger than any single unit is still covered.

Our range

Load banks for sale

Resistive, capacitive, or combined resistive and inductive — load banks made to your spec, bought outright or hired, with or without one of our engineers to run the test. Bespoke designs built to order in 4–6 weeks; call for more info & prices. Models are named by capacity: EGLB100 is a 100kW load bank, EGLB2000 is 2000kW.

100–1500kW built in high-quality soundproof cabinets · 1500–6000kW in soundproofed shipping-container style enclosures · all force air cooled

Every unit is built to a high standard using quality components — stainless steel resistors and H class inductors vacuum impregnated with varnish. All are fitted with Mitsubishi Intelligent control systems, so data recording can be included if you need it. All EGLB load banks are CE certified and manufactured under an ISO9001 quality system. Call with your tech spec and we'll send the correct data sheet — load data, size & weight, cabinet style and extras such as a remote control handset or data recording.

100–4000kW EGLB 100-4000100–4000kW

EGLB 100-4000

Our widest model band, on wheels and easy to position on site, built in a high-quality soundproof cabinet tailor-made to size. From EGLB100 up to EGLB4000 — one small standby set or a 4000kW test.

Capacity
100kW – 4000kW
Load type
Resistive, capacitive or resistive & inductive
Phase
Single or three phase
Enclosure
Soundproof tailor-made cabinet
Cooling
Force air cooled
Resistors
Stainless steel
Inductors
H class, vacuum impregnated
Controls
Mitsubishi Intelligent control system
Get a quote
up to 1500kW EGLB 100 – EGLB 1500up to 1500kW

EGLB 100 – EGLB 1500

The workhorse of the range, built in a high-quality soundproof cabinet tailor-made to the exact capacity you need. Prove single generators, twinsets and larger standby systems at full load.

Capacity
100kW – 1500kW
Load type
Resistive, capacitive or resistive & inductive
Phase
Single or three phase
Enclosure
Soundproof tailor-made cabinet
Cooling
Force air cooled
Resistors
Stainless steel
Inductors
H class, vacuum impregnated
Controls
Mitsubishi Intelligent control system
Get a quote
1500–6000kW EGLB 1500 – EGLB 60001500–6000kW

EGLB 1500 – EGLB 6000

Our largest load banks, built in soundproofed 20ft or 40ft shipping containers with marine-grade painting and a CSC certificate — for big diesel and gas standby sets and data-centre commissioning. Sustained full-load testing from 1500kW to 6000kW.

Capacity
1500kW – 6000kW
Load type
Resistive, capacitive or resistive & inductive
Enclosure
Soundproofed 20ft / 40ft shipping container
Cooling
Force air cooled
Resistors
Stainless steel
Inductors
H class, vacuum impregnated
Controls
Mitsubishi Intelligent control system
Use
Large standby, data centres
Get a quote

Technical specification

EGLB sizes & specifications

Every EGLB size from 100kW to 6000kW, with resistive testing capacities as standard. Call us with your tech spec and we'll send the correct data sheet for the unit you need.

ModelThree phase capacitySingle phase capacityPower factorDimensions (mm)Weight (kg)Inductive PF (optional)Capacitive PF (optional)
EGLB100100 kW22 kW1.0960 × 1150 × 15103500.80.9 or 0.95
EGLB200200 kW44 kW1.01560 × 1310 × 16508400.80.9 or 0.95
EGLB300300 kW66 kW1.01690 × 1440 × 175010850.80.9 or 0.95
EGLB400400 kW88 kW1.01900 × 1600 × 190013500.80.9 or 0.95
EGLB500500 kW110 kW1.01900 × 1600 × 190014000.80.9 or 0.95
EGLB600600 kW132 kW1.02100 × 1730 × 200016000.80.9 or 0.95
EGLB700700 kW154 kW1.02100 × 1730 × 200018000.80.9 or 0.95
EGLB800800 kW176 kW1.02400 × 2030 × 220020200.80.9 or 0.95
EGLB900900 kW198 kW1.02400 × 2030 × 220021500.80.9 or 0.95
EGLB10001000 kW220 kW1.02400 × 2030 × 220022750.80.9 or 0.95
EGLB11001100 kW242 kW1.03500 × 2270 × 215028000.80.9 or 0.95
EGLB12001200 kW264 kW1.03500 × 2270 × 215029000.80.9 or 0.95
EGLB13001300 kW286 kW1.03500 × 2270 × 215030700.80.9 or 0.95
EGLB14001400 kW308 kW1.03500 × 2270 × 215031500.80.9 or 0.95
EGLB15001500 kW330 kW1.03500 × 2270 × 215032500.80.9 or 0.95
EGLB16001600 kW352 kW1.06058 × 2438 × 259158000.80.9 or 0.95
EGLB17001700 kW374 kW1.06058 × 2438 × 259159000.80.9 or 0.95
EGLB18001800 kW396 kW1.06058 × 2438 × 259160000.80.9 or 0.95
EGLB19001900 kW418 kW1.06058 × 2438 × 259161000.80.9 or 0.95
EGLB20002000 kW440 kW1.06058 × 2438 × 259174500.80.9 or 0.95
EGLB21002100 kW462 kW1.06058 × 2438 × 259175000.80.9 or 0.95
EGLB22002200 kW484 kW1.06058 × 2438 × 259176000.80.9 or 0.95
EGLB23002300 kW506 kW1.06058 × 2438 × 259177600.80.9 or 0.95
EGLB24002400 kW528 kW1.06058 × 2438 × 259178600.80.9 or 0.95
EGLB25002500 kW550 kW1.06058 × 2438 × 259181000.80.9 or 0.95
EGLB26002600 kW572 kW1.06058 × 2438 × 259182500.80.9 or 0.95
EGLB27002700 kW594 kW1.06058 × 2438 × 259185000.80.9 or 0.95
EGLB28002800 kW616 kW1.06058 × 2438 × 259190000.80.9 or 0.95
EGLB29002900 kW638 kW1.06058 × 2438 × 259195000.80.9 or 0.95
EGLB30003000 kW660 kW1.06058 × 2438 × 2591105000.80.9 or 0.95
EGLB35003500 kW770 kW1.012192 × 2438 × 2896120000.80.9 or 0.95
EGLB40004000 kW880 kW1.012192 × 2438 × 2896145000.80.9 or 0.95
EGLB45004500 kW990 kW1.012192 × 2438 × 2896165000.80.9 or 0.95
EGLB50005000 kW1100 kW1.012192 × 2438 × 2896175000.80.9 or 0.95
EGLB55005500 kW1210 kW1.012192 × 2438 × 2896185000.80.9 or 0.95
EGLB60006000 kW1320 kW1.012192 × 2438 × 2896200000.80.9 or 0.95
Structure of the EGLB power range — container, cabinet, casters and rack-mount load bank sizes
The EGLB range at a glance — from lightweight rack units and the 100kW on casters, up to 6000kW in shipping-container style enclosures.

Who it's for

Built for critical power

Events & Festivals

Prove temporary power before gates open and the show starts.

Data Centres

Commission and routinely test standby generators and UPS systems.

Healthcare

Evidence your backup power works for compliance and peace of mind.

Construction

Test site generators and distribution before handover.

Standby Commissioning

Full-load testing for new standby and AMF installations.

Generator Servicing

Clear wet-stacking and verify performance after maintenance.

Why Euro Generators

The team that keeps the power on

20+

Years' experience

1000+

Completed projects

800+

Satisfied customers

24/7

Phone manned

Professional team, industry expertise and a client-first process — with delivery, on-site engineers and honest advice on the right test for your equipment. Every unit is built to a high standard using quality components — stainless steel resistors and H class vacuum impregnated inductors — and all fitted with Mitsubishi Intelligent control systems, with data recording options available. All EGLB load banks are CE certified and manufactured under an ISO9001 quality system.

How it works

Four simple steps

  1. 01

    Tell us what you need

    Generator size, site, dates and whether you need an engineer.

  2. 02

    We deliver & connect

    Our team delivers the load bank and connects it safely.

  3. 03

    Test & report

    Step load up to full capacity and record the results.

  4. 04

    We collect

    Once testing is done, we disconnect and collect.

Euro Generators temporary power setup

One supplier

Add a generator to your order

Need the power as well as the proof? Buy your load bank with a generator from 6kVA to bespoke twinsets, plus cable, distribution and fuel — all from one team.

Ask about a package

Get a quote

Buy your load bank

Call us with your specific tech spec and we'll send you the correct data sheet — covering all the load data, size & weight of the unit, cabinet style and individual extra requirements such as a remote control handset or data recording. Load banks can be resistive, capacitive or combined resistive and inductive — we confirm that with you before quoting, so the price covers exactly the right unit.